LOCATION 40 - SYSTEM TIMERS (14 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you
want the duration of the dynamic battery test to be 30 minutes, you should program [3]-
[0]-[*] in segment 1 of this location. The [3]-[0] is the number of minutes; the [*] stores the
data, and moves to the next segment of this location.
Segment 1
Dynamic battery test duration in minutes, 0-255 minutes (“0” = no test)
Segment 2
AC fail report delay in minutes, 0-255 minutes
Segment 3
Power up delay in seconds, 0-60 seconds (“0” = no power up delay)
Segment 4
Siren time in minutes, 1-255 minutes
Segment 5 Telephone line cut delay in seconds, 0-255 seconds (“0” = no
telephone line monitoring enabled)
Segment 6
Cross zone time in minutes, 0-255 (“0” = no cross zoning)
Segment 7 Chime time in 50 msec. (1/ 20th second) increments from 0-12
seconds (“0” = follows zone 255 latched)
Segment 8
Dial delay in seconds, 0-255 seconds (0 no abort delay)
Segment 9 Fire alarm verification time in seconds, 120-255 seconds (“0” = no fire
alarm verification). Values less than 120 sec. are considered as 120
sec.
Segment 10
Listen-in time in seconds, 0-255 (“ 0” = no listen-in time)
Segment 11 Zone activity monitor feature timed in hours/days, 0-255 (“0” =
disabled)
Segment 12
Auto arming warning timer, 1-255 minutes
Segment 13
Auto arming retry timer, 1-255 minutes
Segment 14
Reserved
LOCATION 41 - CODE REQUIREMENTS (1 segment, feature data)
Segment 1
1 =
On: enables the 6-digit code option. If 6-digit option is enabled, all
arm/disarm codes and the “Go To Program Code” are 6 digits. If
this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-
[6]. NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE
“GO TO PROGRAM CODE” IS A SIX-DIGIT CODE BEFORE
YOU EXIT FROM PROGRAMMING
2 =
On: requires code entry for [*]-[9]-[8] (perform callback download)
and [*]-[9]-[9] (answer incoming call for download) functions
3 = Reserved
4 = Reserved
5 = On: keypad shutdown mode
6 = On: user authorisation to enter program mode
7 = On: codes 16 and 17 are guard codes
8 = Reserved
LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the “Go To Program Code”. This location contains a code with either
4 or 6 digits. If the 6-digit code option is enabled in Location 41, THIS CODE MUST
CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments
(digits) will be ignored. With the NX-6 disarmed, the “Go To Program Code” can be used
to enter the Program Mode.