GE Security
g
LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 3 (2 segments, numerical data)
Segment 1, Dial Attempts: Segment 1 of location 15 is used to enter the number of dial
attempts (1 to 15) that the communicator will make to phone N°3 before it ends the
notification process. Factory default is “0”, and the communicator will make the same
number of attempts as those programmed in location 3.
There will be a waiting time of 12 seconds between the first two dial attempts, and
a waiting time of 60 seconds between each subsequent dial attempt (regardless of
the number dialled).
Segment 2, Phone # 3 Backup Control: Programming a “0” in segment 2 of this location
will cause the NX-6 to make the designated number of attempts to phone N°2 before
setting the “Fail To Communicate” condition and stop reporting. Programming a “1” in this
segment will cause the NX-6 to stop trying to communicate after the designated number
of attempts have been made to phone N°3. If a “2” is programmed in this segment, it will
cause the NX-6 to make the dial attempts in increments of two. The first two attempts will
be made to phone N°3, the next two attempts to phone N°2, then repeating until the total
number of attempts designated in segment 1 is completed.
Reporting events to phone number 3
Phone N°3 can be used as a third receiver to multi-report or split report events. Phone
N°3 has two programming locations that are used to select the events that are reported to
this phone number. Location 16 is used to select which events are reported to phone N°3,
and location 17 is used to select which partitions are reported to phone N°3. If you do not
want dual or split reporting, location 16 and location 17 should be left at the factory
default of “0”. If you want multi-reporting or split reporting, and the split is based on the
event type (such as alarm, open/close, etc.), then location 16 should be used to select
only those events that should be reported to phone N°3, and location 17 should be left at
the factory default of “0”. If you want dual or split reporting, and the split is based on
partition, then location 16 should be programmed to “0” and location 17 should be used to
select those partitions that are to be reported to phone N°3. If no events are to be
reported to phone N°3, both locations should be at “0”.