LOADING FACTORY DEFAULTS
To load the factory defaults, enter the program mode using the procedure on page 24,
then type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in
progress. The loading takes about 6 seconds.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the presence of all keypads, zone expanders, wireless
receivers, and any other modules connected to the data terminal can automatically be
found and stored in the NX-6’s memory. This allows the control panel to supervise these
modules. To enroll the modules, enter the program mode for the NX-6 control panel as
described above. If necessary, go on to program the rest of the control panel and the
devices. When you exit from program mode, the control panel will automatically enroll the
devices. The enrolling process takes about 12 seconds, during which time the “Service”
LED will light up. If a module has been enrolled but it is not detected by the control, the
“Service” LED will light up.
PROGRAMMING EXAMPLE (Numerical data)
Zone 1 LED = 1
Zone 4 LED = 8
9
Zone 2 LED = 2
Zone 7 LED = 64
Data = 66 Data =
To cha
in a se
enter the data
followed by [*]
nge data
gment,
Enters the previous
programming “location”
Returns to the “location”
ust programmed
Advances to the next
programming “location”
Pressing [#] will
exit a location
without changing
the data in the
current segment
NX-6-EUR Installation manual Page 28 23/12/04