PROGRAMMING THE NX-6 CONTROL PANEL
Programming the NX-6 control panel via the LED keypad
ENTERING THE PROGRAM MODE
To enter the program mode, press [*]-[8]. When you do this, the five function LED’s (Stay,
Chime, Exit, Bypass, and Cancel) will begin to flash. Next, enter the “Go To Program
Code” (FACTORY DEFAULT IS [9]-[7]-[1]-[3]). If the “Go To Program Code” is valid, the
“Service” LED will flash and the five function LED’s will illuminate steadily. You are now in
the program mode, ready to select the module to be programmed.
Note: it is impossible to enter program mode if any partition - or the system - is armed.
SELECTING THE MODULE TO PROGRAM
Since all the modules connected to the NX-6 are programmed through the keypad, the
module you are programming should be the first entry. To program the NX-6 control
panel, enter [0]-[#]. The [0] is the module number of the control panel and the [#] is the
entry key. Other module entry numbers can be found in the corresponding manuals.
PROGRAMMING A LOCATION
Once you have entered the number of the module to be programmed, the “Armed” LED
will light up, to show that it is waiting for a programming location to be entered. Any
location can be accessed by directly entering the desired programming location, followed
by the crosshatch (pound) [#] key. If the location you enter is valid, the “Armed” LED will
go out, the “Ready” LED will light up, and the binary data for the first segment of this
location will be shown by the zone LED’s. While entering new data, the “Ready” LED will
begin flashing to indicate that a data change is in process. The flashing will continue until
the new data are stored, by pressing the [*] key. When you press the [*] key, the keypad
will advance to the next segment and will display its data. Repeat this procedure until the
last segment is reached. Press the [#] key to exit from this location, and the “Armed” LED
will light up again - this means that it is waiting for a new programming location to be
entered. If you want the next location in the sequence, press the [POLICE] key. If you
want the previous location, press the [FIRE] key. If you want the same location, press the
[MEDIC] key. To review the data in a location, repeat the above procedure, pressing the
[*] key without any numeric data entry. Each time you press the [*] key, the programming
data of the next segment will be displayed for review.
Note: Before programming the panel, the correct country code must be set in loc. 213
EXITING A LOCATION
After the last segment of a location has been programmed, press the [*] key to exit that
location; this turns the “Ready” LED off and the “Armed” LED on. As before, you are now
ready to enter another programming location. If you try to program an invalid entry for a
particular segment, the keypad sounder will emit a triple error beep (beep, beep, beep),
and it will remain in that segment awaiting a valid entry.