Local programming lockout
This feature will disable programming of all locations, or for specified locations, from the
keypad (see location 21).
Log full report
A report can be sent to the central station when the event log is full (see location 37
segment 4).
Lost clock service light
The NX-6 can be programmed to light up the “Service” LED on a LED keypad or give a
“Service” message on a LCD keypad when the internal clock time is invalid due to power
loss. On LCD keypads, if programmed to show the system time, a “Set Clock, *97”
message will always be displayed (see location 37 segment 5).
Manual test
The NX-6 can be programmed to perform a bell and/or communicator test; to do this,
enter [*]-[4]-[4] while the system is in the disarmed state. Each time that [*]-[4]-[4] is
entered, a dynamic battery test will also be performed (see location 37 segment 2).
Night Mode
Applies to NX-1208E / NX-1248E keypads. In this mode, the control panel will bypass all
zones that have the Entry Guard feature enabled. (See location 23 and 111-169)
On board zone disable
The 6 zones on the NX-6 panel can be disabled, in order to obtain a completely wireless
alarm system. A mix of hardwired and wireless zones is also possible (see location 37
segment 5).
Partitions
The NX-6 can be partitioned into a maximum of 2 separate systems with distinct reporting
codes, user codes, and operating features for each system (see locations 26- 36 and
locations 171-205).
Program code
The factory default for the “Go To Program” code is [9]-[7]-[1]-[3] when using a 4-digit
code; or, if the 6-digit option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code
can also be used as an arm/disarm code. If it is used as an arm/disarm code, and if
open/close reports are sent, the user code will be 255 (see location 43).
Quick arm feature
The NX-6 has a single-button “Quick Arm” feature which can be used to arm the system
by pressing the [Exit] key or the [Stay] key on the keypad. If closing reports are sent, the
user code will be 98 (see location 23 segment 1).
Recent closing
If this option is enabled, the NX-6 will send a “Recent Closing Report” to the central
station if an alarm occurs within 5 minutes after the panel is armed. The user number that
was used to arm the system will also be sent (see location 23 segment 3).
Re-exit
The NX-6 can restart the exit delay for a quick exit without the need to disarm the system;
this is done by pressing the [Exit] key while the system is still armed (= after exit delay
has expired). The re-exit is also logged (see location 23 segment 1).
Shutdown
This mode will cause the keypads to extinguish all LED’s, except the “Power” LED, and to
refuse keypresses (see location 21).
NX-6-EUR Installation manual Page 11 23/12/04