LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 2 (2 segments, numerical data)
Segment 1, dial attempts: segment 1 of location 9 is used to enter the number of dial
attempts (1 to 15 attempts) that the communicator will make to phone N°2 before it ends
the notification process. Factory default is “0”, and the communicator will make the same
number of attempts as those programmed in location 3.
There will be a waiting time of 12 seconds between the first two dial attempts, and
a waiting time of 60 seconds between each subsequent dial attempt (regardless of
the number dialled).
Segment 2, phone N° 2 backup control: Programming a “0” in segment 2 of this
location will cause the NX-6 to make the designated number of attempts to phone N°1
before setting the “fail to communicate” condition and stop reporting. Programming a “1”
in this segment will cause the NX-6 to stop trying to communicate after the designated
number of attempts have been made to phone N°2. If a “2” is programmed in this
segment, it will cause the NX-6 to make the dial attempts in increments of two. The first
two attempts will be made to phone N°2, the next two attempts to phone N°1, then
repeating until the total number of attempts designated in segment 1 is completed.
Reporting events to phone number 2
Phone N°2 can be used to back up phone N°1, or as a second receiver to multi-report or
split-report events. Phone N°2 has two programming locations that are used to select the
events that are reported to this phone number. Location 10 is used to select the events
which are reported to phone N°2, and location 11 is used to select which partitions are
reported to phone N°2. If you do not want dual or split reporting, location 10 and location
11 should be left at the factory default of “0”. If you want multi-reporting or split reporting,
and the split is based on the event type (such as alarm, open close etc.), location 10
should be used to select only those events that should be reported to phone N°2, and
location 11 should be left at the factory default of “0”. If you want dual or split reporting,
and the split is based on partition, then location 10 should be programmed as “0”, and
location 11 should be used to select those partitions that are to be reported to phone N°2.
If no events are to be reported to phone N°2, both locations should be at “0”.
LOCATION 10 - EVENTS REPORTED TO PHONE N° 2 (2 segments of feature selection data)
Segment 1
1 = Alarms
2 = Opening and closings
3 = Zone bypass and bypass restores
4 = Zone trouble and trouble restores
5 =
Power fail (AC failure), low battery, power restore (AC restore) ,
and low battery restore
6 = Bell cut, bell cut restore, telephone line restore
7 = Test reports
8 = Start and end programming, download complete and log full