CADDX Ranger 9000E Instalační manuál Strana 19

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 53
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 18
19
DATA 3
CATEGORY
DATA 4
EVENT
DESCRIPTION OF EVENT
"0" "0-15" "OPEN" on individual zones 1 thru 16
"1" "0-15" "OPEN" on individual zones 17 thru 32
"2" "0-15" "SHORT" on individual zones 1 thru 16
"3" "0-15" "SHORT" on individual zones 17 thru 32
"4" "0-15" "OPEN or SHORT" on individual zones 1 thru 16
"5" "0-15" "OPEN or SHORT" on individual zones 17 thru 32
"6" "0-15" "BYPASS" of individual zones 1 thru 16
"7" "0-15" "BYPASS" of individual zones 17 thru 32
"8" "0-15" "TROUBLE" on individual zones 1 thru 16
"9" "0-15" "TROUBLE" on individual zones 17 thru 32
"10" "0-15" "ALARM" on individual zones 1 thru 16
"11" "0-15" "ALARM" on individual zones 17 thru 32
"12" "0" Any "FIRE ALARM"
"1" Any "PANIC ALARM"
"2" Any "BURGLARY ALARM"
"3" Any "TROUBLE CONDITION"
"4" Any "BYPASS REPORT"
"5" Any "EARLY TO OPEN"
"6" Any "LATE TO CLOSE"
"7" "AC FAILURE REPORT"
"8" "DURESS"
"9" "AUXILIARY 1"
"10" "AUXILIARY 2"
"11" "KEYPAD PANIC" (double keypress r and #)
"12" "KEYPAD TAMPER"
"13" "AUTO TEST"
"14" "NOT ARMED"
"15" "CANCEL"
Zobrazit stránku 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 52 53

Komentáře k této Příručce