Page 60
LOC PG DESCRIPTION DEFAULT DATA
107 32 PARTITION 8, ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
108 32
Segment #5
RESERVED
PARTITION 8, ENTRY/EXIT TIMERS
Segment #1
(Entry Time #1)
0
_
Segment #2
(Exit Time #1)
0
_
Segment #3
(Entry Time #2)
0
_
Segment #4
(Exit Time #2)
0
_
109
33
Segment #5 & #6
RESERVED
110 33 ZONE TYPE 1 ALARM EVENT CODE
8
_
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1
(Circle numbers to program)
1
2
3
4
Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour
zone).
Keyswitch zone.
Follower (enable for burg zones that are
instant during non-entry times).
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 1 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Segment #2
(Circle numbers to program)
111 33
1
2
3
4
Keypad audible on alarm.
Yelping siren on alarm.
Temporal siren on alarm.
Chime.
5
6
7
8
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Segment #3
(Circle numbers to program)
1
2
3
4
Fast Loop Response.
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.
5
6
7
8
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.
Segment #4
(Circle numbers to program)
1
2
3
4
Zone Activity Monitor.
End of Line Resistor Defeat.
Reserved.
Reserved.
5
6
7
8
Reserved.
Reserved.
Reserved.
Reserved.
Segment #5
- Reserved