GE Security
g
Segment 5
1 = Reserved
2 = Reserved
3 = Reserved
4 = Reserved
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Entry/Exit timers
) LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Entry time 1
This is the entry time that will be used when a delay
1 zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 2
Entry time 2
This is the exit time that will be used for all zones
designated as delay 1.
Valid entries are 10-255 seconds.
Segment 3
Entry time 3
This is the entry time that will be used when a delay
2 zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 4
Entry time 4
This is the exit time that will be used for all zones
designated as delay 2.
Valid entries are 10-255 seconds.
Segment 5
Reserved
Segment 6
Reserved
NX-4-EUR Installation manual Page 42 08/09/04